New York · Investor-owned utility (electric & gas) · LAST CHECKED 2026-11-07

Consolidated Edison (Con Edison): generator, battery backup & CPAP rules

Service area: New York City's five boroughs and Westchester County

Short answer: Meter collars — Not accepted. Medical program — Life-Support Equipment (LSE) program. Backup battery program — none for medical customers.
Con Edison at a glance
Utility typeInvestor-owned utility (electric & gas)
StateNew York (NY)
ZIP prefixes100, 101, 102, 103, 104, 105, 106, 107, 108, 111, 112, 113, 114
Meter collar policyNot accepted
External disconnect ruleUnder New York's Standardized Interconnection Requirements, an external visible disconnect is required for systems over 25 kW and for non-inverter systems; inverter-based systems such as batteries of 25 kW or less are not covered.
Local gas providerCon Edison (gas) / National Grid in some areas
Medical registryLife-Support Equipment (LSE) program
Battery / generator rebateNone listed for medical customers
Verified official sources7 (checked 2026-11-07)

Why Con Edison prohibits meter collars & what to use instead

Not accepted

Not allowed today. The New York PSC has approved a statewide two-year meter socket adapter pilot (Case 24-E-0526); according to trade press, applications using devices from a utility-approved list may be submitted starting June 1, 2027, with each utility keeping final approval. Standby generator transfer equipment must meet Con Edison's approval.

Con Edison lockable disconnect requirements for generators and batteries

Under New York's Standardized Interconnection Requirements, an external visible disconnect is required for systems over 25 kW and for non-inverter systems; inverter-based systems such as batteries of 25 kW or less are not covered. Standby generators need Con Edison approval first, including a one-line diagram showing how parallel operation is prevented.

Gas meter upgrades for standby generators in the Con Edison area

Gas utility: Con Edison (gas) / National Grid in some areas

No published fee for a generator meter upgrade. Ask your gas utility for a quote.

Quick gas load check

Gas appliances that may run at the same time

Assumes about 14,000 BTU/hr per generator kW at full load and 1,000 BTU per cubic foot of gas; your generator's spec sheet value wins. For dryers, other appliances or a spec-sheet value, use the full gas meter calculator.

Read how gas meter sizing works.

Life-Support Equipment (LSE) program: what Con Edison offers CPAP and oxygen users

Program
Life-Support Equipment (LSE) program
What it provides
Preparedness tips, alerts about possible outages, wellness checks during outages and protection from disconnection. There is no bill credit or discount.
CPAP / BiPAP
Con Edison's examples include apnea monitors and respirators; a licensed medical professional must certify the equipment. CPAP/BiPAP likely qualifies with certification.
Renewal
Con Edison runs a yearly campaign to enroll or re-certify customers; no fixed interval is published.

Backup power options for Con Edison medical customers

We found no backup battery or generator program for medical customers at Con Edison. New York City advises life-support registrants to keep their own backup power.

Plan your own backup: size a battery to your device's wattage and the outage length you want to cover, or pair a generator with a transfer switch your utility accepts. Our CPAP power outage guide walks through the options.

Frequently asked questions

Con Edison does not accept meter collars — can I use a transfer switch or interlock instead?

Not allowed today. The New York PSC has approved a statewide two-year meter socket adapter pilot (Case 24-E-0526); according to trade press, applications using devices from a utility-approved list may be submitted starting June 1, 2027, with each utility keeping final approval. Standby generator transfer equipment must meet Con Edison's approval. Disconnect requirements: Under New York's Standardized Interconnection Requirements, an external visible disconnect is required for systems over 25 kW and for non-inverter systems; inverter-based systems such as batteries of 25 kW or less are not covered. Standby generators need Con Edison approval first, including a one-line diagram showing how parallel operation is prevented.

Who handles gas meter upgrades for a standby generator in the Con Edison area?

Con Edison (gas) / National Grid in some areas No published fee for a generator meter upgrade. Ask your gas utility for a quote.

What does Con Edison's Life-Support Equipment (LSE) program do for CPAP and oxygen users?

Preparedness tips, alerts about possible outages, wellness checks during outages and protection from disconnection. There is no bill credit or discount. CPAP / BiPAP: Con Edison's examples include apnea monitors and respirators; a licensed medical professional must certify the equipment. CPAP/BiPAP likely qualifies with certification.

How Con Edison compares with other Northeast utilities

UtilityMeter collarsMedical programBattery program
Con Edison NY Not accepted Life-Support Equipment (LSE) program —
PSE&G NJ Accepted Life-Sustaining Equipment designation (Critical Care Program) —
Eversource (MA) MA No published rule found Medical Certification of Illness (serious illness shutoff protection) —
PECO PA Restricted / case by case Medical Certification —
BGE MD Accepted Special Needs Programs (certification of serious illness or life support) —