Arizona · Investor-owned utility (electric) · LAST CHECKED 2026-11-07

Arizona Public Service (APS): generator, battery backup & CPAP rules

Service area: Much of Arizona including parts of metro Phoenix (Glendale, Peoria, Scottsdale), Prescott, Flagstaff and Yuma

Short answer: Meter collars — Accepted. Medical program — Medical Care program; Energy Support with Medical (Rider E-4). Backup battery program — none for medical customers.
APS at a glance
Utility typeInvestor-owned utility (electric)
StateArizona (AZ)
ZIP prefixes850, 852, 853, 856, 860, 863
Meter collar policyAccepted
External disconnect ruleGrid-connected generation and storage need an APS-approved visible, lockable disconnect next to the service entrance.
Local gas providerSouthwest Gas
Medical registryMedical Care program; Energy Support with Medical (Rider E-4)
Battery / generator rebateNone listed for medical customers
Verified official sources5 (checked 2026-11-07)

Approved meter collar adapters for APS

Accepted

Allowed with conditions under APS Interconnection Requirements (Rev. 10.0): UL 414 certified, installed by APS or a licensed contractor, self-contained single-phase 120/240 V panel up to 200 A, with a permit. APS has stated it currently allows two types: ConnectDER and the Tesla Backup Switch. Not allowed on panels over 200 A, on poles, or where an adapter already exists.

APS lockable disconnect requirements for generators and batteries

Grid-connected generation and storage need an APS-approved visible, lockable disconnect next to the service entrance. Standby sources on an open-transition transfer switch (UL 1008) or a true double-throw manual switch do not need a separate utility disconnect.

Getting a bigger Southwest Gas meter for a standby generator

Gas utility: Southwest Gas

No published fee for a generator meter upgrade. Southwest Gas service applications ask for each appliance's load in CFH. Ask Southwest Gas for a quote.

Quick gas load check

Gas appliances that may run at the same time

Assumes about 14,000 BTU/hr per generator kW at full load and 1,000 BTU per cubic foot of gas; your generator's spec sheet value wins. For dryers, other appliances or a spec-sheet value, use the full gas meter calculator.

Read how gas meter sizing works.

APS medical program for CPAP, BiPAP and oxygen users

Program
Medical Care program; Energy Support with Medical (Rider E-4)
What it provides
Medical Care: advance notice of planned outages, with no discount. Energy Support with Medical (E-4) is income-qualified only (at or below 200% of federal poverty guidelines) and gives 35% off (max $95 per bill) or 60% off (max $165) depending on income.
CPAP / BiPAP
No device list published; a licensed medical professional completes part of the application.
Renewal
Energy Support: reapply every 24 months.

Backup power options for APS medical customers

We found no backup battery or generator program for medical customers at APS.

Plan your own backup: size a battery to your device's wattage and the outage length you want to cover, or pair a generator with a transfer switch your utility accepts. Our CPAP power outage guide walks through the options.

Frequently asked questions

Which meter collar transfer switches does APS accept?

Accepted. Allowed with conditions under APS Interconnection Requirements (Rev. 10.0): UL 414 certified, installed by APS or a licensed contractor, self-contained single-phase 120/240 V panel up to 200 A, with a permit. APS has stated it currently allows two types: ConnectDER and the Tesla Backup Switch. Not allowed on panels over 200 A, on poles, or where an adapter already exists.

What kind of disconnect switch does APS require for a generator or home battery?

Grid-connected generation and storage need an APS-approved visible, lockable disconnect next to the service entrance. Standby sources on an open-transition transfer switch (UL 1008) or a true double-throw manual switch do not need a separate utility disconnect.

How do I get a bigger Southwest Gas meter for a standby generator?

No published fee for a generator meter upgrade. Southwest Gas service applications ask for each appliance's load in CFH. Ask Southwest Gas for a quote.

What does APS's Medical Care program; Energy Support with Medical (Rider E-4) do for CPAP and oxygen users?

Medical Care: advance notice of planned outages, with no discount. Energy Support with Medical (E-4) is income-qualified only (at or below 200% of federal poverty guidelines) and gives 35% off (max $95 per bill) or 60% off (max $165) depending on income. CPAP / BiPAP: No device list published; a licensed medical professional completes part of the application.

How APS compares with other Arizona utilities

UtilityMeter collarsMedical programBattery program
APS AZ Accepted Medical Care program; Energy Support with Medical (Rider E-4) —
SRP AZ Accepted Medical Preparedness Program —